Cleaning and disinfecting are two separate steps. Cleaning removes dirt, grease, dust, and other contaminants. Disinfecting uses chemicals to destroy bacteria and pathogens. Both steps are recommended for routine maintenance of Axon Interview room equipment.

Each agency should develop and follow its own policies for how frequently to clean and disinfect interview room equipment.

Caution

Power down the device and unplug it from any electrical outlet before cleaning or disinfecting, if possible. Do not get liquids inside the unit. Never spray cleaning products directly onto equipment — apply to a cloth or use pre-dampened wipes.

Clean the equipment

  1. Power down the device and unplug it from any electrical outlet, if possible.
  2. Select a non-abrasive cloth or wipe to avoid scratching surfaces.
  3. Dampen the cloth with an approved cleaning product, or use pre-dampened wipes. Squeeze out any excess moisture before wiping.
  4. Wipe all exterior surfaces.
  5. Allow the surfaces to dry completely before use.
Note

Avoid highly concentrated alcohol (greater than 70%), non-diluted bleach, or ammonia solutions. These may cause discoloration or damage to surfaces.

Disinfect the equipment

  1. Power down the device and unplug it from any electrical outlet, if possible.
  2. Dampen a clean, non-abrasive cloth with a disinfectant from the approved lists below. Squeeze out excess liquid before use. You may also use recommended pre-dampened wipes.
  3. Wipe all exterior surfaces and allow them to dry completely.
  4. Repeat for a second complete cycle.

CDC-recommended disinfectant solutions

The following solutions are approved by the US Centers for Disease Control and Prevention (CDC) and safe for use on Axon Interview room equipment.

  • Household bleach solution (1/3 cup of bleach per gallon of water)
  • Isopropyl alcohol (70% concentration or less)

EPA-recommended disinfectant products

The following products are approved by the US Environmental Protection Agency (EPA) and safe for use on Axon Interview room equipment.

Product EPA Registration No.
Clorox Disinfecting Wipes 5813-79
Clorox Healthcare Bleach Germicidal Wipes 67619-12
Clorox Commercial Solutions Hydrogen Peroxide Cleaner Disinfectant Wipes 67619-25
Lonza Disinfectant Wipes 6836-313
Lysol Brand Clean & Fresh Multi-Surface Cleaner (20% cleaner solution to water ratio) 777-89
Purell Professional Surface Disinfectant Wipes 84150-1
Sani-Cloth Prime Germicidal Disposable Wipes 9480-12

Do not use

The following materials can damage equipment surfaces and must not be used when cleaning or disinfecting Axon Interview room products.

  • Isopropyl alcohol at concentration greater than 70%
  • Methyl alcohol or ethyl alcohol at concentration greater than 35%
  • Thinner or benzine
  • Strong alkali lyes
  • Strong solvents
  • Acids
  • Detergents containing fluoride
  • Detergents containing ammonia at concentration greater than 1.6%
  • Abrasive cleaners or detergents with abrasives
  • Formula 409
  • Steel wool, steel blades, or cloths with steel threads
  • Sponges with abrasive surfaces